Replacing Steam and Hot Water Coils in McQuay Equipment

When the temperature drops, coil calls go up. Steam and hot water coils in fan coils, air handlers, unit ventilators, and hydronic PTACs fail most often in cold weather. Air Distributors supplies coils for McQuay and Daikin Applied equipment.

Why coils fail

  • Freezing. A coil exposed to cold outdoor air, through a stuck damper or a fan that keeps running when the heat is off, can freeze and split.
  • Water hammer and condensate in steam coils. Poor drainage leaves condensate in the coil, which damages tubes.
  • Corrosion. Water chemistry and age wear tubes from the inside.
  • Physical damage during service.

Coil types we supply

  • Steam coils
  • Hot water coils
  • Chilled water coils
  • DX coils
  • Coaxial coils for water source heat pumps
  • Reheat and preheat coils

Coated coils are available for corrosive environments.

What to send

  • The equipment model and serial number. This is how the original coil is identified.
  • Coil type, and number of rows if known
  • Connection sizes and which side they are on
  • Photos of the coil and its connections

Prevent the next one

  • Check outdoor air dampers and freeze protection before winter.
  • Confirm steam traps and condensate drainage work.
  • Keep a spare coil on hand for equipment that has failed before.

Hydronic PTACs need more than a coil? Applied Comfort builds hydronic replacement chassis for many legacy sleeves. See 42 x 16 hydronic PTACs and the McQuay coils page.

Send the model and serial number through the contact form or call 800-866-1210.


More articles

Contact Us

Got a question, or need pricing on a unit or part? Send a message and someone will respond during regular business hours.

800-866-1210

Monday to Friday, 8:30 AM to 4:30 PM Eastern

Include a model and serial number from the unit's nameplate when you have them. That is the fastest way to the right unit or part.

Your information is used only to answer your request. Privacy policy.

Latest Articles

All articles

R-454B and PTAC Replacement: What Changed and What Did Not

New PTACs moved to R-454B refrigerant. For replacement jobs, the change is mostly invisible, with a few things worth knowing.

GE Zoneline AZES vs. AZHS vs. AZVS: Which Series Fits Your Building

All three current GE Zoneline series fit the same 42 x 16 sleeve. The differences are in how they heat and what they cost to run.

Replacing PTACs on the 32 x 18-5/16 Sleeve with the Applied Comfort DM Series

Dozens of discontinued PTAC lines shared one 32-inch sleeve. Here is how the DMQE and DHE replace them without touching the wall.

Get a Quote Call